Inflatable Restraint Instrument Panel Module Replacement
REMOVAL PROCEDURECAUTION: Refer to SIR Inflator Module Handling And Storage Caution In Service Precautions.
1. Disable the SIR system. Refer to Air Bag(s) Arming and Disarming.
2. Remove the upper trim panel.
3. Remove all the inflatable restraint I/P module fasteners (2).
4. Remove the inflatable restraint I/P module (1).
5. Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Inflator Module Handling and Scrapping.
INSTALLATION PROCEDURE
1. Install the inflatable restraint I/P module (1).
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the inflatable restraint I/P module mounting fasteners (2).
Tighten
Tighten fasteners to 2 N.m (18 lb in).
3. Install the I/P upper trim pad.
4. Enable the SIR system. Refer to Air Bag(s) Arming and Disarming.