Charging System Indicators
CHARGEThe IPC illuminates the charge indicator when the following occurs:
^ The PCM detects that the generator output is less than 11 volts or greater than 16 volts. The IPC receives a class 2 message from the PCM requesting illumination.
^ The IPC determines that the system voltage is less than 11 volts or greater than 16 volts.
^ The IPC performs the displays test at the start of each ignition cycle. The indicator illuminates for approximately 3 seconds.
BATTERY NOT CHARGING - 7
The IPC illuminates the BATTERY NOT CHARGING - 7 indicator in the DIC when the PCM detects a malfunction with the generator output. The IPC receives a class 2 message from the PCM requesting illumination.
BATTERY VOLTAGE HIGH - 8
The IPC illuminates the BATTERY VOLTAGE HIGH - 8 indicator in the DIC when the IPC determines that the system voltage is greater than 16 volts.
BATTERY VOLTAGE LOW - 6
The IPC illuminates the BATTERY VOLTAGE LOW - 6 indicator in the DIC when the IPC determines that the system voltage is less than 11 volts.
SERVICE CHARGING SYSTEM - 102
The IPC illuminates the SERVICE CHARGING SYSTEM - 102 indicator in the DIC when the PCM detects a malfunction with the generator output. The IPC receives a class 2 message from the PCM requesting illumination.