B0164
B0164CIRCUIT DESCRIPTION
The inside air temperature sensor provides the HVAC control module with the temperature of the air drawn through an aspirator from the passenger compartment across a sensor. A reference voltage is supplied to the sensor thermistor and the HVAC control module determines the voltage drop across that device which is proportional to temperature. As the air temperature increases, the resistance decreases and the voltage signal decreases. As the air temperature decreases, the resistance increases and the voltage signal increases.
CONDITIONS FOR RUNNING THE DTC
The ignition is turned ON.
CONDITIONS FOR SETTING THE DTC
The HVAC control module detects the inside air temperature sensor signal circuit is less than 2 counts or greater than 253 counts for 30 seconds.
ACTION TAKEN WHEN THE DTC SETS
- If the DTC sets due to the low condition, the HVAC control module will default to maximum cooling, except when the maximum heating setting is selected.
- If the DTC sets due to the high condition, the HVAC control module will default to maximum heating, except when the maximum cooling setting is selected.
CONDITIONS FOR CLEARING THE DTC
- The DTC will become history if the HVAC control module no longer detects a failure.
- The history DTC will clear after 50 fault free ignition cycles.
- The DTC can be cleared with a scan tool.
DIAGNOSTIC AIDS
If the condition is not present, refer to Diagnostic Aids for Circuit Testing and Wiring Repair procedures.
TEST DESCRIPTION
Steps 1 - 3:
Steps 4 - 7:
Steps 8 - 13:
The numbers below refer to the step numbers on the diagnostic table.
3. Tests for the proper operation of the circuit in the high voltage range.
4. Tests for the proper operation of the circuit in the low voltage range. If the fuse in the jumper opens when you perform this test, the signal circuit is shorted to voltage.