Blower Motor Replacement (Lhd)
BLOWER MOTOR REPLACEMENT (LHD)REMOVAL PROCEDURE
1. Remove the right closeout insulator panel.
2. Remove the IP compartment.
3. Disconnect the blower motor electrical connector.
4. Disconnect the blower motor processor electrical connector.
5. Remove the screws (1) that retain the blower motor.
6. Remove the air inlet housing bolts to gain clearence for the blower motor.
7. Remove the blower motor.
INSTALLATION PROCEDURE
1. Install the blower motor.
2. Install the blower motor screws (1).
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the screws to 1.5 N.m (13 lb in).
3. Install the air inlet housing bolts.
Tighten
Tighten the screws to 6 N.m (53 lb in).
4. Connect the blower motor processor electrical connector.
5. Connect the blower motor electrical connector.
6. Install the IP compartment.
7. Install the right closeout insulator panel.