Refrigerant Pressure Sensor / Switch: Service and Repair
AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENTTOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant.
IMPORTANT: There is no schrader valve under the pressure sensor.
2. Remove the air cleaner assembly.
3. Disconnect the electrical connector (1) from the A/C refrigerant pressure sensor (2).
4. Remove the A/C refrigerant pressure sensor.
INSTALLATION PROCEDURE
1. Lubricate the O-ring with refrigerant oil.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the A/C refrigerant pressure sensor (2).
Tighten
Tighten the sensor to 9.8 N.m (87 lb in).
3. Connect the electrical connector (1) to the A/C refrigerant pressure sensor.
4. Install the air cleaner assembly.
5. Evacuate and recharge the A/C system.
6. Leak test the fittings of the component using J 39400-A.