Defroster Door Replacement
DEFROSTER DOOR REPLACEMENTREMOVAL PROCEDURE
1. Remove the HVAC Module.
2. Remove the recirculation door.
3. Remove the mode actuator.
4. Remove the upper module case screws.
5. Peel back the foam at the heater inlet.
6. Remove the upper case.
7. Remove the actuator cam from the defroster door.
8. Remove the defroster door.
INSTALLATION PROCEDURE
1. Install the defroster door.
2. Install the actuator cam to the defroster door.
3. Install the upper module case.
NOTE: Refer to Fastener Notice in Service Precautions.
4. Install the upper module case screws.
Tighten
Tighten the screws to 1.4 N.m (12 lb in).
5. Apply the foam at the heater inlet.
6. Install the mode actuator.
7. Install the recirculation door.
8. Install the HVAC module.
9. Recalibrate the actuators. Refer to Body Control Module (BCM) Programming/RPO Configuration (IPM)Body Control Module (BCM) Programming/RPO Configuration (DIM)Body Control Module (BCM) Programming/RPO Configuration (RIM) in Body Control System. Re-Calibrating Actuators - HVAC System - Automatic