A/C Refrigerant Low Temperature Sensor Replacement
AIR CONDITIONING (A/C) REFRIGERANT LOW TEMPERATURE SENSOR REPLACEMENTTOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant.
2. Disconnect the electrical connector from the A/C low temperature sensor.
3. Unscrew the A/C low temperature sensor from the refrigerant line.
INSTALLATION PROCEDURE
1. Install the A/C low temperature sensor to the refrigerant line.
2. Connect the electrical connector to the A/C low temperature sensor.
3. Recharge the A/C system.
4. Leak test the fittings of the repaired or reinstalled component using J 39400-A.