Roof Diagnosis
DTC B1011
Circuit Description
Battery positive voltage is supplied to the folding top control (FTC) module from the BAT MAIN 2 fuse. When commanded, this voltage is used by the FTC module to power the folding top pump motor through the motor control circuits. When an overcurrent condition is detected, the FTC module disables the folding top pump motor in order to protect the internal FTC module circuitry.
DTC Descriptor
This diagnostic procedure supports the following DTC.
DTC B1011 System Disabled Information Stored
Conditions for Running the DTC
The FTC module monitors for overcurrent only when the power folding top pump motor is active.
Conditions for Setting the DTC
The FTC module will set DTC B1011 when the measured current exceeds 81-amps for 100 milliseconds.
Action Taken When the DTC Sets
^ All folding top functions in progress are aborted, including calibrations of the folding top.
^ The FTC module will suspend operation of the folding top pump motor.
Conditions for Clearing the DTC
^ The DTC will clear on the current status after the condition for setting the fault is corrected.
^ A history DTC will clear after 50 consecutive ignition cycles without a fault present.
^ A history and current DTC can be cleared using the scan tool.
Diagnostic Aids
Perform a visual inspection for loose or poor connections at all related components.
Test Description
The numbers below refer to the step numbers on the diagnostic table.
3. This test determines if the suspect motor has an internal short to ground.
9. This test verifies the repair.