Scan Tool Data Definitions
SCAN TOOL DATA DEFINITIONS
Battery Voltage Signal - Inputs: The scan tool displays 0-16 Volts. The voltage measured between the module's battery positive voltage and ground circuits.
Current: The scan tool displays 0-127.5 Amps. The amount of amps used by the selected seat motors during operation.
Driver Heated Seat Status - HVAC: The scan tool displays Off/High/MED/Low. When the driver cheated seat is on, the scan tool displays the driver heated seat status signal from the driver position module to the climate control panel as High or Low.
Driver Heated Seat Sw. - HVAC: The scan tool displays Idle/Pressed. When the driver heated seat switch is pressed, the scan tool momentarily displays the switch input to the climate control panel as Pressed.
Driver Seat Front Vertical Sensor: The scan tool displays 0-255 Counts. The sensor potentiometer provides an analog count value which varies directly with the seat front vertical position. High scan tool count values indicate that the front of the seat cushion is in the upward position, while low count values indicate that the front of the seat cushion is in the downward position.
Driver Seat Front Vertical Sensor: The scan tool displays 0-5.0 Volts. The sensor potentiometer provides an analog voltage which varies directly with the seat front vertical position. High scan tool voltage values indicate that the front of the seat cushion is in the upward position while low voltage values indicate that the front of the seat cushion is in the downward position.
Driver Seat Horizontal Sensor: The scan tool displays 0-5.0 Volts. The sensor potentiometer provides an analog voltage which varies directly with the seat horizontal position. High scan tool voltage values indicate that the seat is in the forward position, while low voltage values indicate that the seat is in the rearward position.
Driver Seat Horizontal Sensor: The scan tool displays 0-255 Counts. The sensor potentiometer provides an analog count value which varies directly with the seat horizontal position. High scan tool count values indicate that the seat is in the forward position, while low count values indicate that the seat is in the rearward position.
Driver Seat Lumbar Horizontal Sensor: The scan tool displays 0-5.0 Volts. The sensor potentiometer provides an analog voltage which varies directly with the seat lumbar horizontal position. High scan tool voltage values indicate that the lumbar support is in the forward position, while low voltage values indicate that the lumbar support is in the rearward position.
Driver Seat Lumbar Horizontal Sensor: The scan tool displays 0-255 Counts. The sensor potentiometer provides an analog count value which varies directly with the seat lumbar horizontal position. High scan tool count values indicate that the lumbar support is in the forward position, while low count values indicate that the lumbar support is in the rearward position.
Driver Seat Lumbar Vertical Sensor: The scan tool displays 0-5.0 Volts. The sensor potentiometer provides an analog voltage which varies directly with the seat lumbar vertical position. High scan tool voltage values indicate that the lumbar support is in the upward position, while low voltage values indicate that the lumbar support is in the downward position.
Driver Seat Lumbar Vertical Sensor: The scan tool displays 0-255 Counts. The sensor potentiometer provides an analog count value which varies directly with the seat lumbar vertical position. High scan tool count values indicate that the lumbar support is in the upward position, while low count values indicate that the lumbar support is in the downward position.
Driver Seat Rear Vertical Sensor: The scan tool displays 0-5.0 Volts. The sensor potentiometer provides an analog voltage which varies directly with the seat rear vertical position. High scan tool voltage values indicate that the rear of the seat cushion is in the upward position while low voltage values indicate that the rear of the seat cushion is in the downward position.
Driver Seat Rear Vertical Sensor: The scan tool displays 0-255 Counts. The sensor potentiometer provides an analog count value which varies directly with the seat rear vertical position. High scan tool count values indicate that the rear of the seat cushion is in the upward position, while low count values indicate that the rear of the seat cushion is in the downward position.
Driver Seat Recline Sensor: The scan tool displays 0-5.0 Volts. The sensor potentiometer provides an analog voltage which varies directly with the seat recline position. High scan tool voltage values indicate that the seat recline is forward, while low voltage values indicate that the seat recline is rearward.
Driver Seat Recline Sensor: The scan tool displays 0-255 Counts.The sensor potentiometer provides an analog count value which varies directly with the seat recline position. High scan tool count values indicate that the seat recline is forward, while low count values indicate that the seat recline is rearward.
Driver Vented Seat Status - HVAC: The scan tool displays Off/High/MED/Low. When the driver vented seat is on, the scan tool displays the driver vented seat status signal from the driver position module to the climate control panel as High or Low.
Driver Vented Seat Sw. - HVAC: The scan tool displays Idle/Pressed. When the driver vented seat switch is pressed, the scan tool momentarily displays the switch input to the climate control panel as Pressed.
Drvr. Seat Front Vertical Motor Command: The scan tool displays Inactive/Upward/Downward. When the seat front vertical switch is pressed, the scan tool displays the driver position module output control of the seat front vertical motor as selected, Upward or Downward.
Drvr. Seat Front Vertical Switch: The scan tool displays Inactive/Upward/Downward. When the seat front vertical switch is pressed, the scan tool displays the switch input to the driver position module as selected, Upward or Downward.
Drvr. Seat Horizontal Motor Command: The scan tool displays Inactive/Forward/Rearward. When the seat horizontal switch is pressed, the scan tool displays the driver position module output control of the seat horizontal motor as selected, Forward or Rearward.
Drvr. Seat Horizontal Switch: The scan tool displays Inactive/Forward/Rearward. When the seat horizontal switch is pressed, the scan tool displays the switch input to the driver position module as selected, Forward or Rearward.
Drvr. Seat Lumbar Horizontal Motor Command : The scan tool displays Inactive/Forward/Rearward. When the seat lumbar horizontal switch is pressed, the scan tool displays the driver position module output control of the lumbar horizontal motor as selected, Forward or Rearward.
Drvr. Seat Lumbar Horizontal Switch: The scan tool displays Inactive/Forward/Rearward. When the seat lumbar horizontal switch is pressed, the scan tool displays the switch input to the driver position module as selected, Forward or Rearward.
Drvr. Seat Lumbar Vertical Motor Command: The scan tool displays Inactive/Upward/Downward. When the seat lumbar vertical switch is pressed, the scan tool displays the driver position module output control of the lumbar vertical motor as selected, Upward or Downward.
Drvr. Seat Lumbar Vertical Switch: The scan tool displays Inactive/Upward/Downward. When the seat lumbar vertical switch is pressed, the scan tool displays the switch input to the driver position module as selected, Upward or Downward.
Drvr. Seat Rear Vertical Motor Command: The scan tool displays Inactive/Upward/Downward. When the seat rear vertical switch is pressed, the scan tool displays the driver position module output control of the seat rear vertical motor as selected, Upward or Downward.
Drvr. Seat Rear Vertical Switch: The scan tool displays Inactive/Upward/Downward. When the seat rear vertical switch is pressed, the scan tool will display the switch input to the driver position module as selected, Upward or Downward.
Drvr. Seat Recline Motor Command: The scan tool displays Inactive/Forward/Rearward. When the seat recline switch is pressed, the scan tool displays the driver position module output control of the seat recline motor selected, Forward or Rearward.
Drvr. Seat Recline Switch: The scan tool displays Inactive/Forward/Rearward. When the seat recline switch is pressed, the scan tool displays the switch input to the driver position module as selected, Forward or Rearward.
Horizontal Value - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the seat horizontal position sensor voltage value that is stored in memory for driver 1.
Horizontal Value - Memory Data 1: The scan tool displays 0-255 Counts. This parameter displays the seat horizontal position sensor count value that is stored in memory for driver 1.
Horizontal Value - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the seat horizontal position sensor voltage value that is stored in memory for driver 2.
Horizontal Value - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the seat horizontal position sensor count value that is stored in memory for driver 2.
Pass. Vented Seat Status - HVAC: The scan tool displays Off/High/MED/Low. When the passenger vented seat is on, the scan tool displays the passenger vented seat status signal from the driver position module to the climate control panel as High or Low.
Pass. Vented Seat Switch - HVAC: The scan tool displays Idle/Pressed. When the passenger vented seat switch is pressed, the scan tool momentarily displays the switch input to the climate control panel as Pressed.
Pass. Heated Seat Status - HVAC: The scan tool displays Off/High/MED/Low. When the passenger heated seat is on, the scan tool displays the passenger heated seat status signal from the driver position module to the climate control panel as High or Low.
Pass. Heated Seat Switch - HVAC: The scan tool displays Idle/Pressed. When the passenger heated seat switch is pressed, the scan tool momentarily displays the switch input to the climate control panel as Pressed.
Seat Front Vertical Exit Position - Memory Data Default: The scan tool displays 5.0 Volts. This parameter value is the default voltage value that is displayed for manufacturing purposes.
Seat Front Vertical Exit Position - Memory Data Default: The scan tool displays 255 Counts. This parameter value is the default count value that is displayed for manufacturing purposes.
Seat Front Vertical Exit Position - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 1.
Seat Front Vertical Exit Position - Memory Data 1: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 1.
Seat Front Vertical Exit Position - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 2.
Seat Front Vertical Exit Position - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 2.
Seat Front Vertical Position - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 1.
Seat Front Vertical Position - Memory Data 1: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 1.
Seat Front Vertical Position - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 2.
Seat Front Vertical Position - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 2.
Seat Horizontal Exit Position - Memory Data Default: The scan tool displays 5.0 Volts. This parameter value is the default voltage value that is displayed for manufacturing purposes.
Seat Horizontal Exit Position - Memory Data Default: The scan tool displays 255 Counts. This parameter value is the default count value that is displayed for manufacturing purposes.
Seat Horizontal Exit Position - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 1.
Seat Horizontal Exit Position - Memory Data 1: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 1.
Seat Horizontal Exit Position - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 2.
Seat Horizontal Exit Position - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 2.
Seat Lumbar Horizontal Position - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the lumbar horizontal position sensor voltage value that is stored in memory for driver 1.
Seat Lumbar Horizontal Position - Memory Data 1: The scan tool displays 0-255 Counts. This parameter displays the lumbar horizontal position sensor count value that is stored in memory for driver 1.
Seat Lumbar Horizontal Position - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the lumbar horizontal position sensor voltage value that is stored in memory for driver 2.
Seat Lumbar Horizontal Position - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the lumbar horizontal position sensor count value that is stored in memory for driver 2.
Seat Lumbar Vertical Position - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the lumbar vertical position sensor voltage value that is stored in memory for driver 1.
Seat Lumbar Vertical Position - Memory Data 1: The scan tool displays 0-255 Counts. This parameter displays the lumbar vertical position sensor count value that is stored in memory for driver 1.
Seat Lumbar Vertical Position - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the lumbar vertical position sensor voltage value that is stored in memory for driver 2.
Seat Lumbar Vertical Position - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the lumbar vertical position sensor count value that is stored in memory for driver 2.
Seat Rear Vertical Exit Position - Memory Data Default: The scan tool displays 5.0 Volts. This parameter value is the default voltage value that is displayed for manufacturing purposes.
Seat Rear Vertical Exit Position - Memory Data Default: The scan tool displays 255 Counts. This parameter value is the default count value that is displayed for manufacturing purposes.
Seat Rear Vertical Exit Position - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 1.
Seat Rear Vertical Exit Position - Memory Data 1: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 1.
Seat Rear Vertical Exit Position - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 2.
Seat Rear Vertical Exit Position - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 2.
Seat Rear Vertical Position - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 1.
Seat Rear Vertical Position - Memory Data 1 : The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 1.
Seat Rear Vertical Position - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 2.
Seat Rear Vertical Position - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 2.
Seat Recline Exit Position - Memory Data Default: The scan tool displays 5.0 Volts. This parameter value is the default voltage value that is displayed for manufacturing purposes.
Seat Recline Exit Position - Memory Data Default: The scan tool displays 255 Counts. This parameter value is the default count value that is displayed for manufacturing purposes.
Seat Recline Exit Position - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 1.
Seat Recline Exit Position - Memory Data 1: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 1.
Seat Recline Exit Position - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 2.
Seat Recline Exit Position - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 2.
Seat Recline Position - Memory Data 1: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 1.
Seat Recline Position - Memory Data 1: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 1.
Seat Recline Position - Memory Data 2: The scan tool displays 0-5.0 Volts. This parameter displays the position sensor voltage value that is stored in memory for driver 2.
Seat Recline Position - Memory Data 2: The scan tool displays 0-255 Counts. This parameter displays the position sensor count value that is stored in memory for driver 2.