Air Door: Service and Repair
AIR INLET ASSEMBLY REPLACEMENT
REMOVAL PROCEDURE
1. Remove the IP compartment.
2. Remove the closeout panel.
3. Remove the upper air inlet assembly bolts (1).
4. Remove the lower right air inlet assembly bolt (1).
5. Slide the assembly to the right and then lower.
6. Disconnect the air inlet assembly electrical connector (1).
7. Rotate the air inlet assembly (1) and remove.
INSTALLATION PROCEDURE
1. Connect the air inlet assembly electrical connector (1).
2. Install the air inlet assembly (1) to the locator pin.
3. Install the upper air inlet assembly bolts (1).
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the bolt to 9 N.m (80 lb in)
4. Install the lower right air inlet assembly bolt (1).
Tighten the bolt to 9 N.m (80 lb in)
5. Install the IP compartment.
6. Install the closeout panel.