Instrument Panel (I/P) - Upper Right
AIR OUTLET DUCT REPLACEMENT - INSTRUMENT PANEL (I/P) - UPPER RIGHT
REMOVAL PROCEDURE
1. Remove the IP retainer.
2. Remove the foam dash pad (1).
3. Disconnect the wiring harness from the air duct (1).
4. Remove the screws (1) that retain the air duct (2).
5. Remove the right air duct (2), by releasing the tabs from the module.
INSTALLATION PROCEDURE
1. Install the right air duct (2), by pressing down until you hear the tabs engage on the HVAC module.
2. Install the right air duct screws (1).
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 2 N.m (18 lb in).
3. Connect the wiring harness to the air duct (1).
4. Install the foam dash pad (1).
5. Install the IP retainer.