P0406
DTC P0406
CIRCUIT DESCRIPTION
The engine control module (ECM) uses the exhaust gas recirculation (EGR) position sensor to determine the position of the EGR valve. The ECM sends a reference voltage through the 5-Volt reference circuit to the EGR position sensor. The ECM provides a voltage return path for the sensor through the low reference circuit. A variable voltage signal, based on the EGR valve position, is sent from the sensor to the ECM through the EGR position sensor signal circuit. If the ECM detects an EGR position sensor voltage that is more than the normal operating range, DTC P0406 sets.
DTC DESCRIPTOR
This diagnostic procedure supports the following DTC:
DTC P0406 Exhaust Gas Recirculation (EGR) Position Sensor Circuit High Voltage
CONDITIONS FOR RUNNING THE DTC
- DTCs P0641 and P0651 are not set.
- The Ignition 1 Signal parameter is between 11-18 volts.
- The engine is running.
- The EGR flow test is not running.
- DTC P0406 runs continuously once the above conditions are met.
CONDITIONS FOR SETTING THE DTC
The EGR position sensor voltage is more than 4.77 volts for more than 18 seconds.
ACTION TAKEN WHEN THE DTC SETS
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.
TEST