P0051
DTC P0051
CIRCUIT DESCRIPTION
Heating elements inside the heated oxygen sensor (HO2S) minimize the time required for the sensors to reach operating temperature and provide an accurate voltage signal. A low side driver within the engine control module (ECM) is pulse width controlled to provide current to the heater elements. The ECM will not allow continuous HO2S heating until calibrated limits of time, temperature, and intake airflow have been reached. The ECM continuously monitors the HO2S heater operating state by briefly turning OFF the heater low side driver at regular intervals. A small reference voltage of approximately 4.5 volts is present at the heater low control circuit. When the low side driver is commanded ON, the reference voltage is low, when the low side driver is commanded OFF the reference voltage is high, close to battery voltage. If the ECM detects that the HO2S heater low control circuit voltage is lower than 2.6 volts when the heater is commanded OFF, the following DTCs will set:
- DTC P0031 for HO2S bank 1 sensor 1
- DTC P0037 for HO2S bank 1 sensor 2
- DTC P0051 for HO2S bank 2 sensor 1
- DTC P0057 for HO2S bank 2 sensor 2
DTC DESCRIPTORS
This diagnostic procedure supports the following DTCs:
- DTC P0031 HO2S Heater Control Circuit Low Voltage Bank 1 Sensor 1
- DTC P0037 HO2S Heater Control Circuit Low Voltage Bank 1 Sensor 2
- DTC P0051 HO2S Heater Control Circuit Low Voltage Bank 2 Sensor 1
- DTC P0057 HO2S Heater Control Circuit Low Voltage Bank 2 Sensor 2
CONDITIONS FOR RUNNING THE DTC
- The engine is running.
- Battery voltage is more than 10 volts.
- DTC P0031, P0037, P0051, or P0057 runs continuously once the above conditions are met.
CONDITIONS FOR SETTING THE DTC
The ECM detects that the HO2S heater low control circuit voltage is below 2.6 volts when the heater is commanded OFF, indicating an HO2S heater circuit shorted to ground.
ACTION TAKEN WHEN THE DTC SETS
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.
TEST