Closeout/Insulator Panel Replacement - Right
Closeout/Insulator Panel Replacement - Right
Removal Procedure
1. Remove the screws securing the insulator to the instrument panel.
2. Disconnect the courtesy lamp electrical connector (1).
Installation Procedure
1. Connect the courtesy lamp electrical connector (1).
2. Locate the insulator panel onto the Instrument panel.
Notice: Refer to Fastener Notice in Cautions and Notices.
3. Install the screws securing the instrument panel.
Tighten the screws to 2 N.m (18 lb in).