Camshaft Position Actuator Solenoid Replacement - Bank 1 (Right Side) Exhaust
Camshaft Position Actuator Solenoid Replacement - Bank 1 (Right Side) Exhaust
Removal Procedure
1. Turn the ignition OFF.
2. Remove the camshaft position (CMP) actuator valve electrical connector.
3. Remove the CMP actuator valve bolt.
4. Remove the CMP actuator valve.
5. Inspect the CMP actuator valve seal for damage. Replace the seal if necessary.
Installation Procedure
1. Inspect the CMP actuator valve seal for damage. Replace the seal if necessary.
2. Install the CMP actuator valve.
Notice: Refer to Fastener Notice.
3. Install the CMP actuator valve bolt.
Tighten the CMP actuator valve bolt to 10 N.m (89 lb in).
4. Install the CMP valve electrical connector.