Instrument Cluster / Carrier: Service and Repair
Instrument Cluster Replacement
Removal Procedure
1. Remove the instrument panel (I/P) cluster trim cover.
2. Remove the screws (2) securing the cluster to the I/P.
3. Install a small flat bladed tool (1) between the I/P cluster and the I/P.
4. Pry up on the I/P in order to release the retainers on the cluster.
5. Pull out on the cluster and disconnect the electrical connectors.
Installation Procedure
1. Position the cluster on the I/P.
2. Connect the electrical connectors (1) on the back of the cluster.
3. Push the cluster into the I/P in order to lock in the cluster retainers.
Notice: Refer to Fastener Notice.
4. Install the fasteners (2) in order to secure the cluster to the I/P.
Tighten the fasteners to 2 N.m (18 lb in).
5. Refer to Programming and RelearningProgramming and Relearning