B1024
DTC B1024
DTC Descriptor
DTC B1024 11
- Circuit Board Temperature Sensor above maximum threshold
Circuit/System Description
The internal amplifier circuitry is monitored for temperature. If the amplifier senses an over-heat condition higher than 95°C (203°F) of the internal circuitry, the amplifier will shut down until the internal circuitry cools below 90°C (194°F).
Conditions for Running the DTC
The following are conditions that must be present in order for the radio to enable the diagnostics.
* The radio is in ACCESSORY, RUN, or RAP power mode.
* The system voltage is at least 9 volts and no more than 16 volts.
Conditions for Setting the DTC
Amplifier senses an over-heat condition higher than 95°C (203°F) of the internal circutry
Action Taken When the DTC Sets
Amplifier mutes all speaker channels.
Conditions for Clearing the DTC
* The condition must be corrected.
* A history DTC clears after 100 malfunction-free ignition cycles.
* The amplifier receives the clear code command from the scan tool.
Circuit/System Verification
The amplifier should operate normally at a reasonably high volume for an extended period of time.
Circuit/System Testing
Extended use of extremely high volume, especially in warm weather conditions, may induce this DTC. Under these conditions it may be normal for this DTC to set to prevent permanent damage to the amplifier circuitry. If DTC persists without excessive volume, replace the amplifier.
Repair Instructions
Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests
Programming and Relearning for Audio Amplifier setup, and programming. Programming and Relearning