Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Exhaust
CAMSHAFT POSITION ACTUATOR SOLENOID VALVE SOLENOID REPLACEMENT - BANK 1 (RIGHT SIDE) EXHAUST
REMOVAL PROCEDURE
1. Turn the ignition OFF.
2. Remove the front compartment sight shields as necessary.
3. Disconnect the camshaft position (CMP) actuator valve electrical connector.
4. Remove the CMP actuator valve bolt.
5. Remove the CMP actuator valve.
6. Inspect the CMP actuator valve seal for damage. Replace the seal if necessary.
INSTALLATION PROCEDURE
1. Inspect the CMP actuator valve seal for damage. Replace the seal if necessary.
2. Install the CMP actuator valve.
3. Install the CMP actuator valve bolt.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the bolt to 10 Nm (89 lb in).
4. Connect the CMP valve electrical connector.
5. Install the front compartment sight shields as necessary.