130. Water Outlet Housing Installation
Water Outlet Housing Installation
1. Place the water outlet housing in place while fitting the bypass hose to the engine front cover.
Notice: Refer to Fastener Notice
2. Install the water outlet housing bolts to the cylinder heads.
Tighten the water outlet housing bolts to 25 N.m (18 lb ft).
3. Reposition the clamp (1) on the bypass hose. Ensure the clamp release mechanism of the clamps are oriented towards the engine front cover and away from the drive belt path.