B2961
DTC B2961
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview)provides an overview of each diagnostic category.
DTC Descriptors
DTC B2961 02
- Key In Ignition Circuit Short to Ground
Diagnostic Fault Information
Circuit/System Description
The remote control door lock receiver (RCDLR) applies voltage to the key capture solenoid under specific conditions to allow the ignition to be turned OFF.
Conditions for Running the DTC
The ignition transitions from OFF to ON.
Conditions for Setting the DTC
The RCDLR detects the key in ignition circuit is active for greater than 3 minutes.
Action Taken When the DTC Sets
The key in ignition input is ignored.
Conditions for Clearing the DTC
* A current DTC will clear when the condition for setting the DTC is no longer present.
* A history DTC will clear after 40 malfunction-free ignition cycles.
Reference Information
Schematic Reference
Shift Lock Control Schematics ([1][2]Electrical Diagrams)
Connector End View Reference
Component Connector End Views (Connector Views)
Description and Operation
Automatic Transmission Shift Lock Control Description and Operation (Description and Operation)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
Scan Tool Reference
Control Module References (Programming and Relearning)for scan tool information
Circuit/System Verification
Ignition ON, observe the scan tool RCDLR Authentication Switch parameter. The parameter should be Active only when the ignition switch knob is pressed.
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the ignition switch.
2. Ignition ON, verify the scan tool Authentication Switch parameter is Inactive.
• If not the specified value, test the signal circuit terminal 5 for a short to voltage. If the circuit tests normal, replace the RCDLR.
3. Install a 3A fused jumper wire between the signal circuit terminal 5 and B+. Verify the scan tool Authentication Switch parameter is Active.
• If not the specified value, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the RCDLR.
4. If all circuits tests normal, test or replace the ignition switch.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
* Ignition and Start Switch Replacement (Ignition and Start Switch Replacement)
* Control Module References (Programming and Relearning)for RCDLR replacement, setup, and programming