B3601
DTC B3601
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.
DTC Descriptors
DTC B3601 01
- Ignition Switch Key Capture Solenoid Circuit Short to Battery
DTC B3601 02
- Ignition Switch Key Capture Solenoid Circuit Short to Ground
Diagnostic Fault Information
Circuit/System Description
The remote control door lock receiver (RCDLR) applies voltage to the key capture solenoid under specific conditions to allow the ignition to be turned ON or OFF.
Conditions for Running the DTC
This DTC runs in all ignition modes
Conditions for Setting the DTC
B3601 01
The RCDLR detects a voltage level on the control circuit greater than 8 volts when the key capture solenoid is commanded OFF.
B3601 02
The RCDLR detects a voltage level on the control circuit less than 2 volts when the key capture solenoid is commanded ON.
Action Taken When the DTC Sets
* The key capture solenoid output is disabled.
* SERVICE KEYLESS START SYSTEM is displayed on the DIC.
Conditions for Clearing the DTC
* A current DTC will clear when the condition for setting the DTC is no longer present.
* A history DTC will clear after 40 malfunction-free ignition cycles.
Reference Information
Schematic Reference
Shift Lock Control Schematics ([1][2]Electrical Diagrams)
Connector End View Reference
Component Connector End Views (Connector Views)
Description and Operation
Automatic Transmission Shift Lock Control Description and Operation (Description and Operation)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
Scan Tool Reference
Control Module References (Programming and Relearning) for scan tool information
Circuit/System Verification
Command the Key Capture Solenoid ON and OFF with the scan tool while attempting to cycle the igniting from OFF to ON. The ignition knob should rotate when the solenoid is commanded ON and should not rotate when the solenoid is commanded OFF.
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the key capture solenoid.
2. Test for less than 5 ohms between the ground circuit terminal 1 and ground.
• If greater than the specified range, test the ground circuit for an open/high resistance.
3. Connect a test lamp between the control circuit terminal 2 and the ground circuit terminal 1.
4. Command the Key Capture Solenoid ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
• If the test lamp is always ON, test the control circuit for short to voltage. If the circuit tests normal, replace the RCDLR.
• If the test lamp is always OFF, test the control circuit for short to ground or an open/high resistance. If the circuit tests normal, replace the RCDLR.
5. If all circuits tests normal, test or replace the key capture solenoid.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
Control Module References (Programming and Relearning) for RCDLR replacement, setup, and programming