Daytime Running Lamps Malfunction
Daytime Running Lamps Malfunction
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.
Diagnostic Fault Information
Circuit/System Description
Daytime Running Lamps without HID
The ambient light sensor is used to monitor outside lighting conditions. The ambient light sensor provides a voltage signal that will vary between 0.2 and 4.9 volts depending on outside lighting conditions. The HVAC control module provides a low reference ground and 5-volt reference signals to the ambient light sensor. The body control module (BCM) monitors the ambient light sensor signal circuit to determine if outside lighting conditions are correct for either daytime running lights (DRL) or automatic lamp control (ALC) when the headlamp switch is in the AUTO position. In daylight conditions the BCM will command the low beam headlamps ON. Any function or condition that turns on the headlamps will cancel DRL operation.
Daytime Running Lamps with HID
The ambient light sensor is used to monitor outside lighting conditions. The ambient light sensor provides a voltage signal that will vary between 0.2 and 4.9 volts depending on outside lighting conditions. The HVAC control module provides a low reference ground and 5-volt reference signals to the ambient light sensor. The body control module (BCM) monitors the ambient light sensor signal circuit to determine if outside lighting conditions are correct for either daytime running lights (DRL) or automatic lamp control (ALC) when the headlamp switch is in the AUTO position. In daylight conditions, the BCM will command the DRLs ON by applying ground to the left and right DRL relays via separate left and right DRL relay control circuits. When the BCM applies ground to the relay control circuits, the left and right DRL relay coils energize causing both relay switch contacts to close. With the left and right DRL relay switch contacts closed, battery voltage flows through the left and right DRL fuses to the left and right DRL lamps. Any function or condition that turns on the headlamps will cancel DRL operation.
Diagnostic Aids
Important: This diagnostic procedure assumes that the low beam headlamps are operating within specifications. If the low beam headlamps are inoperative, diagnose the low beam headlamp malfunction before proceeding with the following diagnostic. Refer to Headlamps Malfunction (Headlamps Malfunction) .
Reference Information
Schematic Reference
Headlights/Daytime Running Lights (DRL) Schematics (Headlights/Daytime Running Lights (DRL) Schematics)
Connector End View Reference
Component Connector End Views (Connector Views)
Description and Operation
Exterior Lighting Systems Description and Operation (Exterior Lighting Systems Description and Operation)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
Scan Tool Reference
Control Module References (Programming and Relearning) for scan tool information
Circuit/System Verification
Ignition ON, verify with a scan tool the park brake switch parameter displays RELEASED.
If not the specified value, refer to Symptoms - Hydraulic Brakes (Symptoms - Hydraulic Brakes) .
Circuit/System Testing
Daytime Running Lamps without HID
1. Ignition OFF, disconnect the harness connector at the sunload sensor assembly.
2. Ignition OFF, scan tool OFF, doors CLOSED, test for less than 20.0 ohms between the low reference circuit terminal C and ground.
• If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
3. Reconnect the sunload sensor assembly harness connector.
4. Ignition ON, verify the scan tool ambient light sensor parameter is greater than 0.2 volts.
• If less than the specified range, test the signal circuit terminal D for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.
5. Verify the scan tool ambient light sensor parameter is less than 4.9 volts.
• If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the BCM.
6. If all circuits test normal, replace the sunload sensor assembly.
Daytime Running Lamps with HID
1. Ignition OFF, disconnect the appropriate DRL relay.
2. Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal 87 and ground.
• If the test lamp illuminates, test the control circuit for a short to voltage.
3. Verify that a test lamp illuminates between the B+ circuit terminal 30 and ground.
• If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 87 for a short to ground. If the circuit tests normal, test or replace the appropriate DRL relay.
4. Verify that a test lamp illuminates between the B+ circuit terminal 85 and ground.
• If the test lamp does not illuminate, test the B+ circuit for an open/high resistance.
5. Ignition OFF, disconnect the harness connector at the inoperative DRL.
6. Ignition OFF, exterior lamps OFF, test for less than 5.0 ohms between the inoperative DRL ground circuit terminal B and ground.
• If greater than the specified range, test the ground circuit for an open/high resistance.
7. Connect the harness connector at the inoperative DRL.
8. Connect a 15A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the appropriate DRL is activated.
• If the DRL does not activate, test the control circuit for an open/high resistance. If the circuit tests normal, replace the inoperative DRL.
9. Connect a test lamp between the B+ circuit terminal 85 and the relay control circuit terminal 86.
10. Ignition ON, vehicle in DRIVE, place a bright incandescent lamp over the ambient light sensor and verify the appropriate DRL is illuminated.
• If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.
• If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM.
11. If all circuits test normal, test or replace the inoperative DRL relay.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
* Headlamp Automatic Control Ambient Light Sensor Replacement (Service and Repair)
* Headlamp Assembly or Headlamp Bulb and/or Cornering, Sidemarker, Park, Turn Signal Bulb Replacement (Minus TT6/TT7/TT8/T84/T85) (Service and Repair)Headlamp Assembly or Headlamp Bulb and/or Cornering, Sidemarker, Park, Turn Signal Bulb Replacement (T84/T85) (Service and Repair)Headlamp Assembly or Headlamp Bulb and/or Cornering, Sidemarker, Park, Turn Signal Bulb Replacement (TT6) (Service and Repair)Headlamp Assembly or Headlamp Bulb and/or Cornering, Sidemarker, Park, Turn Signal Bulb Replacement (TT8) (Service and Repair)Headlamp Assembly or Headlamp Bulb and/or Cornering, Sidemarker, Park, Turn Signal Bulb Replacement (TT7) (Service and Repair)
* Control Module References (Programming and Relearning) for BCM or HVAC control module replacement, setup, and programming