65. Valve Lifter Cleaning and Inspection
Valve Lifters Cleaning and Inspection
Notice: Refer to Valve Lifter Priming Notice.
1. Inspect the stationary hydraulic lash adjuster (SHLA) in the following areas:
* A plugged oil passage (1)
* A scored or worn camshaft follower pivot area (2)
* A damaged or broken retainer (3), some applications
* A severely scuffed or worn SHLA body (4)
2. Replace the SHLA or SHLAs as necessary.