Operation CHARM: Car repair manuals for everyone.

21. Camshaft Position Actuator Housing Removal - Left Side



Camshaft Position Actuator Housing Removal - Left Side






Notice: DO NOT remove the camshaft position actuator magnet unless it needs to be replaced. The camshaft position actuator magnet is precisely aligned to the camshaft position actuator oil control valve on the end of the camshaft during engine assembly. If the camshaft position actuator magnet is removed and/or needs to be replaced, it will be necessary to realign the camshaft position actuator magnet to the camshaft position actuator oil control valve after the camshaft position actuator housing is installed to the cylinder head. Failure to realign the camshaft position actuator magnet to the camshaft position actuator oil control valve can lead to poor engine performance and engine component damage.

1. Remove the left camshaft position actuator housing bolts.
2. Remove the left camshaft position actuator housing.