Windshield Defroster Duct Replacement
Windshield Defroster Duct Replacement
Removal Procedure
1. Remove the instrument panel (I/P) assembly. Refer to Instrument Panel Carrier Replacement (Service and Repair) .
2. Remove the retainers from the RH defogger upper outlet duct.
3. Disconnect and remove the RH defogger upper outlet duct from the RH defogger lower outlet duct.
4. Disconnect the RH defogger lower outlet duct from the SIR bracket.
5. Disconnect the RH defogger lower outlet duct from the defroster duct.
6. Remove the RH defogger lower outlet duct.
7. Remove the windshield defroster duct retaining screws.
8. Disconnect the defroster duct from the LH defogger lower outlet duct.
9. Remove the defroster duct.
Installation Procedure
Important: If installing a new defroster duct, remove the protective plastic film from the defroster duct before installing.
1. Install the defroster duct.
2. Connect the defroster duct to the LH defogger lower outlet duct.
Notice: Refer to Fastener Notice (Fastener Notice) .
3. Install the retaining screws to the windshield defroster duct.
Tighten the screws to 2 N.m (18 lb in).
4. Install the RH defogger lower outlet duct.
5. Connect the RH defogger lower outlet duct to the defroster duct.
6. Connect the RH defogger lower outlet duct to the SIR bracket.
7. Connect the RH defogger upper outlet duct to the RH defogger lower outlet duct.
8. Install the retainers to the RH defogger upper outlet duct.
9. Install the I/P assembly. Refer to Instrument Panel Carrier Replacement (Service and Repair) .