Without RPO NC1 or NF7
Exhaust Manifold Installation - Left Side (W/O RPO NC1 or NF7)
Caution: Refer to Fastener Caution (Fastener Caution).
1. If the engine is equipped with coolant heaters, install the left side (1) heater as follows:
1. Place the coolant heater (1) in position on the cylinder block.
2. Install the coolant heater bolt and tighten to 10 Nm (89 lb in).
2. With the manifold still on the bench, position a new manifold gasket (1) in place on the manifold sealing surface.
3. Install 2 outer manifold bolts (6) in the manifold to retain the gasket.
4. Install a new manifold to intermediate pipe flange gasket (5).
5. Using 2 hands, place the manifold (2) in the intermediate pipe and onto the cylinder head.
6. Install new manifold flange bolts (3) for maximum joint integrity. Hand tighten. Do not torque the flange bolts to specification until the engine is mounted in the vehicle.
7. Hand tighten the 2 outer manifold bolts.
8. Install the remaining manifold bolts. Tighten the exhaust manifold bolts (6) to 25 Nm (18 lb ft).
9. Coat the oxygen sensor threads with high temperature anti-seize, GM P/N 12377953 or equivalent.
10. Install the oxygen sensor (1) and tighten to 40 Nm (30 lb ft).