66. Oil Pump Cleaning and Inspection
Oil Pump Cleaning and Inspection
Cleaning Procedure
1. Clean the oil pump components (1-8) with non-corrosive solvent.
Warning: Refer to Safety Glasses Warning (Safety Glasses Warning).
2. Dry the oil pump components with compressed air.
Inspection Procedure
Note: The internal parts of the oil pump are not serviced separately. If wear or damage is noted, replace the entire pump assembly.
1. Clean the oil pump components with non-corrosive solvent.
2. Inspect the housing (1) and the cover (6) for cracks, scoring, casting imperfections and damaged threads.
3. Inspect the gerotor gears (5) for chipping, galling or wear.
4. Inspect the pressure relief valve (2) for embedded particles and/or damage.