Clock Malfunction
Clock Malfunction
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Diagnostic System Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Strategy Based Diagnosis) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Diagnostic Procedure Instructions)provides an overview of each diagnostic category.
Diagnostic Fault Information
Circuit/System Description
The instrument panel is equipped with an analog clock. The analog clock utilizes the clock battery positive voltage circuit and the clock ground circuit to operate. An open circuit condition, a high resistance or a short to ground in the battery positive voltage circuit or the ground circuit will cause the clock not to operate properly.
Reference Information
Schematic Reference
Instrument Cluster Schematics (Instrument Cluster Schematics)
Connector End View Reference
Component Connector End Views (Connector End Views By Name)
Description and Operation
Instrument Cluster Description and Operation (Instrument Cluster)
Electrical Information Reference
* Circuit Testing (Circuit Testing)
* Connector Repairs (Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (Wiring Repairs)
Scan Tool Reference
Control Module References (Programming and Relearning)for scan tool information
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the clock.
2. Ignition OFF, test for less than 1 ohm between the ground circuit terminal 2 and ground.
• If greater than the specified range, test the ground circuit for an open/high resistance.
3. Verify that a test lamp illuminates between the B+ circuit terminal 1 and the ground circuit terminal 2.
• If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
4. If all circuits test normal, replace the clock.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
Clock Replacement (Service and Repair)