65. Manual Link and Wire Harness Connection
Manual Link and Wire Harness Connection
Note: Failure to use a new manual valve link retainer may cause the manual valve link assembly to become disconnected.
1. Install a new manual valve link retainer (915) onto the detent lever (17).
2. Connect the manual valve link (913) to the detent lever (17).
3. Connect the wire harness extension (943) to the upper control wire harness (12).
4. Tuck the harness and connectors into the case cavity.