High Intensity Discharge Lamp Malfunction
High Intensity Discharge Lamp Malfunction
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Diagnostic System Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Strategy Based Diagnosis) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Diagnostic Procedure Instructions) provides an overview of each diagnostic category.
Diagnostic Fault Information
Circuit/System Description
With the headlamp switch in the ON position, the headlamp switch headlamp ON signal circuit is grounded through the turn signal/multifunction switch. In response to this input, the instrument panel module provides ground to either the headlamp low beam relay control circuit or the headlamp high beam relay control circuit. The position of the headlamp dimmer switch determines which relay coil has ground. The instrument panel module supplies ground to the relay coil circuits, if the headlamps are necessary. The underhood fuse block supplies battery positive voltage to both relay switch circuits. When the low beam relay coil is energized, current flows through the LT LOW BEAM and the RT LOW BEAM fuses to the low beam headlamps.
Diagnostic Aids
The following symptoms are noticeable signs of bulb failure:
* Flickering light, caused in the early stages of bulb failure.
* Lights go out, caused when the ballast detects excessive, repetitive bulb re-strike.
* Color change-The lamp may change to a dim pink glow.
Reference Information
Schematic Reference
* Headlights/Daytime Running Lights (DRL) Schematics (Headlights/Daytime Running Lights (DRL) Schematics)
* Inside Rearview Mirror Schematics (Inside Rearview Mirror Schematics)
Connector End View Reference
Component Connector End Views (Connector End Views By Name)
Description and Operation
Exterior Lighting Systems Description and Operation (Exterior Lighting Systems)
Electrical Information Reference
* Circuit Testing (Circuit Testing)
* Connector Repairs (Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (Wiring Repairs)
Scan Tool Reference
Control Module References (Programming and Relearning) for scan tool information
Circuit/System Testing
Warning
The high intensity discharge system produces high voltage and current. To reduce the risk of severe shocks and burns:
* Never open the high intensity discharge system ballast or the arc tube assembly starter.
* Never probe between the high intensity discharge system ballast output connector and the arc tube assembly.
1. Ignition OFF, disconnect the HID Relay.
2. Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal 86 and ground.
• If the test lamp illuminates, test the control circuit for a short to voltage.
3. Verify that a test lamp illuminates between the B+ circuit terminal 85 and ground.
• If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
4. Verify that a test lamp illuminates between the B+ circuit terminal 30 and ground.
• If the test lamp does not illuminate, test the B+ circuit for an open/high resistance.
5. Disconnect the harness connector at the inoperative headlamp.
6. Test for less than 5 ohm between the headlamp ground circuit terminal 4 and ground.
• If greater than the specified range, test the ground circuit for an open/high resistance.
7. Connect the harness connector at the headlamp.
8. Connect a 20 A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the headlamp - low beam is activated.
• If the headlamp - low beam does not activate and the jumper wire fuse is good, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the headlamp.
• If the headlamp - low beam does not activate and the jumper wire fuse is open, test the control circuit for a short to ground. If the circuit tests normal, test or replace the headlamp.
9. Connect a test lamp between the B+ circuit terminal 85 and the control circuit terminal 86.
10. Command the Low Beams ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
• If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the instrument panel module.
• If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the instrument panel module.
11. If all circuits test normal, test or replace the HID Relay.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
* Relay Replacement (Attached to Wire Harness) (Relay Replacement (Attached to Wire Harness))Relay Replacement (Within an Electrical Center) (Relay Replacement (Within an Electrical Center))
* Headlamp Ballast Replacement (STS) (Headlamp Ballast Replacement (STS))
* Headlamp Replacement (Headlamp Replacement)
* Control Module References (Programming and Relearning) for instrument panel module replacement, setup and programming