Water Pump: Service and Repair
Water Pump Replacement (LFX)
Special Tools
EN 46104 Water Pump Pulley Holding Tool
Removal Procedure
1. Drain the cooling system. Refer to Cooling System Draining and Filling (Static Fill LSA) Service and RepairCooling System Draining and Filling (GE 47716 LSA) Service and RepairCooling System Draining and Filling (Static Fill LF1, LLT,LFW or LFX) Service and RepairCooling System Draining and Filling (GE 47716 LF1, LLT,LFW or LFX) Service and Repair.
2. Remove the generator drive belt. Refer to Drive Belt Replacement Service and Repair.
3. Use the EN 46104 (1) in order to retain the water pump pulley.
4. Remove the water pump pulley bolts.
5. Remove the water pump pulley.
6. Remove the water pump bolts.
7. Remove the water pump.
8. Remove and DISCARD the water pump seal.
9. Carefully clean the water pump sealing surfaces.
Installation Procedure
1. Install a NEW water pump seal.
2. Install the water pump.
Caution: Refer to Fastener Caution Fastener Caution.
3. Hand tighten the water pump bolts.
4. Tighten the water pump bolts in sequence to 12 Nm (106 lb in).
5. Tighten the water pump bolts a second pass in sequence to 12 Nm (106 lb in).
6. Install the water pump pulley and the water pump pulley bolts.
7. Use the EN 46104 (1) in order to retain the water pump pulley.
8. Install the water pump pulley bolts and tighten to 12 Nm (106 lb in).
9. Install the generator drive belt. Refer to Drive Belt Replacement Service and Repair.
10. Fill the cooling system. Refer to Cooling System Draining and Filling (Static Fill LSA) Service and RepairCooling System Draining and Filling (GE 47716 LSA) Service and RepairCooling System Draining and Filling (Static Fill LF1, LLT,LFW or LFX) Service and RepairCooling System Draining and Filling (GE 47716 LF1, LLT,LFW or LFX) Service and Repair.