B0158
DTC B0158
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.
DTC Descriptors
DTC B0158 02
- Ambient Air Temperature Sensor Circuit Short to Ground
DTC B0158 05
- Ambient Air Temperature Sensor Circuit High Voltage/Open
Diagnostic Fault Information
Circuit/System Description
The instrument cluster monitors the ambient air temperature sensor with a low reference circuit and signal circuit. The instrument cluster monitors the voltage drop across the sensor, which is inversely proportional to temperature. When the ambient air temperature is cold, the resistance of the sensor is high. When the ambient air temperature is warm, the resistance of the sensors is low. The instrument cluster converts the voltage value to a temperature value and displays the temperature.
Conditions for Running the DTC
The system voltage is between 9-16 V.
Conditions for Setting the DTC
B0158 02
The instrument cluster detects the sensor signal is more than 88°C (190°F).
B0158 05
The instrument cluster detects the sensor signal is less than -40°C (-40°F).
Action Taken When the DTC Sets
The instrument cluster uses a default air temperature value for further calculations. The instrument cluster will display -°C (-°F).
Conditions for Clearing the DTC
The DTC will become history if the instrument cluster no longer detects a malfunction.
Reference Information
Schematic Reference
Instrument Cluster Schematics Instrument Cluster Schematics
Connector End View Reference
Component Connector End Views Fuel Pump and Level Sensor Assembly
Description and Operation
Instrument Cluster Description and Operation Instrument Cluster
Electrical Information Reference
* Circuit Testing Circuit Testing
* Connector Repairs Connector Repairs
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections
* Wiring Repairs Wiring Repairs
Scan Tool Reference
Control Module References Control Module References for scan tool information
Circuit/System Testing
1. Ignition OFF and all vehicle systems OFF, disconnect the harness connector at the B9 ambient air temperature sensor. It may take up to 2 minutes for all vehicle systems to power down.
2. Test for less than 10 ohms between the low reference circuit terminal B and ground.
• If 10 ohms or greater
1. Ignition OFF, disconnect the harness connector at the P16 instrument cluster.
2. Test for less than 2 ohms in the low reference circuit end to end.
• If 2 ohms or greater, repair the open/high resistance in the circuit.
• If less than 2 ohms, replace the P16 instrument cluster.
• If less than 10 ohms
3. Ignition ON.
4. Verify the scan tool Ambient Air Temperature parameter is greater than 98%.
• If 98% or less
1. Ignition OFF, disconnect the harness connector at the P16 instrument cluster.
2. Test for infinite resistance between the signal circuit terminal A and ground.
• If less than infinite resistance, repair the short to ground on the circuit.
• If infinite resistance, replace the P16 instrument cluster.
• If greater than 98%
5. Install a 3 A fused jumper wire between the signal circuit terminal A and the low reference circuit terminal B.
6. Verify the scan tool Ambient Air Temperature parameter is less than 8%.
• If 8% or greater
1. Ignition OFF, disconnect the harness connector at the P16 instrument cluster, ignition ON.
2. Test for less than 1 V between the signal circuit and ground.
• If 1 V or greater, repair the short to voltage on the circuit.
• If less than 1 V
3. Ignition OFF
4. Test for less than 2 ohms in the signal circuit end to end.
• If 2 ohms or greater, repair the open/high resistance in the circuit.
• If less than 2 ohms, replace the P16 instrument cluster.
• If less than 8%
7. Test or replace the B9 ambient air temperature sensor.
Repair Instructions
Perform the Diagnostic Repair Verification Verification Tests after completing the repair.
* Ambient Air Temperature Gauge Sensor Replacement Ambient Air Temperature Gauge Sensor Replacement
* Control Module References Control Module References for instrument cluster replacement, programming and setup