Service Port HVAC: Service and Repair
SERVICE PORT VALVE CORE REPLACEMENTTOOLS REQUIRED
^ J 34611-A Valve Core Remover and Installer
^ J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging .
2. Remove the service port valve core using J 34611-A.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Service Precautions.
1. Install the service port valve core using J 34611-A.
Tighten
Tighten the service core to 11 N.m (98 lb in).
2. Recharge the air conditioning (A/C) system. Refer to Refrigerant Recovery and Recharging .
3. Leak test the fittings of the component using the J 39400-A.