Operation CHARM: Car repair manuals for everyone.

Inflatable Restraint Instrument Panel Module Replacement



Inflatable Restraint Instrument Panel Module Replacement

Removal Procedure

Caution: Refer to SIR Inflator Module Handling and Storage Caution.

Caution: Refer to Restraint System Service Precautions.

1. Disable the SIR system. Refer to SIR Disabling and Enabling.
2. Remove the instrument panel (I/P) assembly.
3. Remove the connector position assurance (CPA) from the I/P module harness connector.
4. Disconnect the pigtail connector from the I/P module.




5. Remove the mounting fasteners from the I/P module.
6. Remove the I/P module from the bracket.
7. Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Inflator Module Handling and Scrapping.

Installation Procedure




1. Install the I/P module to the bracket.

Notice: Refer to Fastener Notice.

2. Install the I/P module mounting fasteners. Tighten the fasteners in the order shown in the graphic.

Tighten the fasteners to 10 N.m (89 lb in).

3. Connect the pigtail connector to the I/P module.
4. Install the CPA to the harness connector on the I/P module.
5. Install the I/P assembly.
6. Enable the SIR system. Refer to SIR Disabling and Enabling.