Operation CHARM: Car repair manuals for everyone.

Air Recirculation Malfunction



Air Recirculation Malfunction

Diagnostic Aids

* The condition may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections in Diagnostic Aids. Component Tests and General Diagnostics
* Inspect the air delivery system for the following conditions:

- An obstruction to the airflow
- Air leaks
- Misaligned air ducts
- Broken or binding linkages or doors

* If the scan tool indicates that the Door Actual parameter is 5-10 counts from the Commanded Door parameter, then perform the recalibration procedure for the HVAC door actuators. Refer to Re-Calibrating Actuators. Programming and Relearning

Test

Step 1 - Step 5: