Operation CHARM: Car repair manuals for everyone.

Blower Motor Resistor: Service and Repair



Blower Motor Resistor Replacement

Removal Procedure




Caution: Refer to Battery Disconnect Caution (Battery Disconnect Caution).
1. Disconnect the negative battery cable.
2. Disconnect the electrical connector at the resistor.
3. Remove the retaining screws from the resistor.
4. Remove the resistor by gently pulling it downward.


Installation Procedure





Notice: Refer to Fastener Notice (Fastener Notice).

1. Install the new resistor into the heater/air distribution case with the screws.

Tighten the blower resistor retaining screws to 6 N.m (53 lb in).

2. Connect the electrical connector at the resistor.
3. Connect the negative battery cable.
4. Confirm the proper performance of the blower.