Operation CHARM: Car repair manuals for everyone.

P0622



DTC P0622

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
* Review Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC P0622
- Generator F-Terminal Circuit

Diagnostic Fault Information






Typical Scan Tool Data






Circuit/System Description

The engine control module (ECM) uses the generator field duty cycle signal circuit to monitor the duty cycle of the generator. The generator field duty cycle signal circuit connects to high side of the field windings in the generator. A pulse width modulated (PWM) high side driver in the voltage regulator turns the field windings ON and OFF. The ECM uses the PWM signal input to determine the generator load on the engine. This allows the ECM to adjust the idle speed to compensate for high electrical loads. The ECM monitors the status of the generator field duty cycle signal circuit. When the key is in the RUN position and the engine is OFF, the ECM should detect a duty cycle near 0 percent. However, when the engine is running, the duty cycle should be between 5-99 percent.

Conditions for Running the DTC

* The engine is running.
* Engine speed is less than 3,000 RPM.
* No generator, crankshaft position (CKP) sensors, or camshaft (CMP) sensor DTCs are set.

Conditions for Setting the DTC

The ECM detects a PWM signal less than 5 percent for 30 seconds.

Action Taken When the DTC Sets

* DTC P0622 is a C type DTC.
* The charge indicator turns ON.

Conditions for Clearing the DTC

DTC P0622 is a C type DTC.

Circuit/System Verification

With the scan tool installed, ignition ON and the Engine running, observe the scan tool ECM GEN-F Terminal Signal parameter. The parameter should read between 5 and 95 percent.

Circuit/System Testing

1. Ignition OFF, disconnect the generator harness connector.
2. Ignition ON and engine OFF, connect a test lamp to B+ and repeatedly probe the generator field duty cycle circuit terminal 2, harness side while monitoring the GEN-F Terminal Signal Parameter. It should change from 0 percent to 99 percent.

If the circuit tests normal, replace the generator.

If the parameter was not affected by the test lamp, test the circuit for a short to voltage, short to ground, or an open/high resistance.

3. If the circuit tests normal, replace the ECM.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests

* Generator Replacement (RPOs L61/LE5)