P0650
DTC P0650
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
* Review Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions provide an overview of each diagnostic category.
DTC Descriptor
DTC P0650
- Malfunction Indicator Lamp (MIL) Control Circuit
Diagnostic Fault Information
Circuit/System Description
The malfunction indicator lamp (MIL) is located on the instrument panel cluster (IPC).
The MIL informs the driver that an emission system fault has occurred and that the engine control system requires service. The engine control module (ECM) monitors the MIL control circuit for conditions that are incorrect for the commanded states of the MIL.
Conditions for Running the DTC
DTC P0650 runs continuously when the ignition is ON and the ignition voltage is between 11-18 volts.
Conditions for Setting the DTC
The ECM detects that the commanded state of the MIL driver and the actual state of the control circuit do not match for 6 seconds.
Action Taken When the DTC Sets
DTC P0650 is a type B DTC, with no MIL request.
Conditions for Clearing the MIL/DTC
DTC P0650 is a type B DTC, with no MIL request.
Circuit/System Verification
1. Ignition ON, the MIL should turn ON and OFF when commanded with a scan tool.
2. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
Circuit/System Testing
1. Ignition ON, verify that the IPC warning indicators are illuminated.
^ If the IPC warning indicators are not illuminated, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, replace the IPC.
2. Ignition OFF, disconnect connector X1 at the electronic ECM.
3. Ignition ON, verify that the MIL is not illuminated.
^ If the MIL is illuminated inspect the MIL control circuit for a short to ground. If the circuit tests normal, replace the IPC.
4. Ignition ON, verify that the MIL illuminates with a 3A fused jumper between the MIL control circuit X1-12 and ground.
^ If the MIL does not illuminate test the MIL control circuit for a short to voltage or an open/high resistance. If the circuit tests normal replace the ECM.
Repair Instructions
Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests
* Instrument Cluster Replacement