Folding Top Manual Operation
Folding Top Manual Operation
Manually Moving the Folding Top from the Down Position
Important: Allow the system a minimum of four minutes to bleed down pressure after the last cycle.
1. Manually release the folding top cover latch using the emergency release cable.
2. Raise the folding top stowage cover.
3. Manually raise the folding top, holding the 5 bow up.
4. Manually lower and latch the folding top stowage cover.
5. Manually unfold the top and latch per normal procedure.
Manually Moving the Folding Top from the Up Position
Important: Allow the system a minimum of four minutes to bleed down pressure after the last cycle.
1. Manually release header latch per normal operation.
2. Manually lift front of roof off of the header and raise the #5 bow at the same time.
3. Manually release the Folding Top Cover latch using the emergency release cable.
4. Fold the roof down into the well.
5. Manually close and latch the folding top stowage cover.