Operation CHARM: Car repair manuals for everyone.

Instrument Cluster Gages Inoperative



Instrument Cluster Gages Inoperative

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.



Circuit/System Description

This diagnostic procedure applies to serial data gages located in the instrument panel cluster (IPC) which include the engine coolant temperature gage and the volt gage.


Reference Information
Schematic Reference

Instrument Cluster Schematics (Instrument Cluster Schematics)
Connector End View Reference

Component Connector End Views (Connector Views)
Description and Operation

Instrument Cluster Description and Operation (Description and Operation)
Electrical Information Reference

* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)

Scan Tool Reference

Control Module References (Programming and Relearning)


Circuit/System Testing

Ignition ON, with the scan tool, perform the IPC Gage Sweep Test in the IPC Output Controls. Verify that all gage dials move from minimum to the gage maximum value and back to the gage minimum value.

If all the gages do not perform the IPC Gage Sweep Test, replace the IPC.



Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.


Control Module References (Programming and Relearning) for the IPC replacement, setup and programming