B2530



DTC B2530

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
* Review Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC B2530 02
- Front Foglamps Control Circuit Short to Ground

DTC B2530 05
- Front Foglamps Control Circuit Short to Battery or Open

Diagnostic Fault Information






Circuit/System Description

The front fog lamp switch signal circuit is grounded momentarily by pressing the front fog lamp switch. The body control module (BCM) energizes the front fog lamp relay by applying battery positive voltage to the front fog lamps relay control circuit when the front fog lamp relay is energized, battery positive voltage is applied to the front fog lamps supply voltage circuit which illuminates the front fog lamps.

Conditions for Running the DTC

The battery voltage must be between 9-16 volts.

Conditions for Setting the DTC

B2530 02

The front fog lamp relay control circuit is shorted to ground.

B2530 05

The front fog lamp relay control circuit is shorted to battery positive voltage or open.

Action Taken When the DTC Sets

B2530 02

The front fog lamps will not operate.

B2530 05

The front fog lamps and the fog lamp indicator will be on at all times or will not operate.

Conditions for Clearing the DTC

* This DTC will clear on current status after the condition for setting the fault is corrected.
* A history DTC will clear after 100 consecutive ignition cycles without a fault present.

Circuit/System Testing

1. Ignition OFF, disconnect the FRT FOG relay.
2. Test for less than 5 ohms between the ground circuit terminal B and ground.

^ If greater than the specified range, test the ground circuit for an open/high resistance.

3. Connect a test lamp between the ground circuit terminal B and the control circuit terminal A.
4. Command the front fog lamps ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.

^ If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
^ If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.

5. If all circuits test normal, test or replace the FRT FOG relay.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests

* Relay Replacement (Attached to Wire Harness)