DTC 1
DTC 1
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview)provides an overview of each diagnostic category.
DTC Descriptors
DTC 1
- Passenger Compartment Temperature Sensor Circuit
Diagnostic Fault Information
Circuit/System Description
The HVAC control module supplies the inside air temperature sensor with a low reference circuit and 5-volt signal circuit. The HVAC control module determines the voltage drop across the sensor, which is proportional to temperature. As the air temperature increases, the sensor resistance decreases and the voltage signal decreases. As the air temperature decreases, the sensor resistance increases and the voltage signal increases.
Passenger compartment temperature sensor refers to the inside air temperature sensor.
Conditions for Running the DTC
The ignition is turned ON.
Conditions for Setting the DTC
The HVAC control module detects the inside air temperature sensor signal circuit is less than -36°C (-38°F) or greater than 215°C (419°F) for greater than 15 seconds.
Action Taken When the DTC Sets
The system operates using a default value.
Conditions for Clearing the DTC
* The DTC will become history if the HVAC control module no longer detects the condition that set the DTC.
* The history DTC will clear after 100 fault-free ignition cycles.
Reference Information
Schematic Reference
HVAC Schematics (HVAC - Automatic)
Connector End View Reference
Component Connector End Views (Connector Views)
Description and Operation
Automatic HVAC Description and Operation (HVAC - Automatic)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
Scan Tool Reference
Control Module References (Programming and Relearning)for scan tool information
Circuit/System Verification
Ignition ON, observe the scan tool Inside Air Temperature Sensor parameter. The reading should be between -35°C (-39°F) and 98°C (208°F) and change with inside air temperature changes.
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the inside air temp sensor.
2. Ignition OFF, test for less than 10 ohms between the low reference circuit terminal 1 and ground.
• If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
3. Ignition ON, verify the scan tool inside Air Temp. Sensor parameter is less than -35°C (-39°F).
• If greater than the specified range, test the signal circuit terminal 2 for a short to ground. If the circuit tests normal, replace the HVAC control module.
4. Install a 3A fused jumper wire between the signal circuit terminal 2 and the low reference circuit terminal 1. Verify the scan tool Inside Air Temp. Sensor parameter is greater than 85°C (185°F).
• If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
5. If all circuits test normal, test or replace the inside air temp sensor.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
* Inside Air Temperature Sensor Replacement (Service and Repair)
* Control Module References (Programming and Relearning)for HVAC control module replacement, setup and programming