Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview)provides an overview of each diagnostic category.

DTC Descriptors
DTC 2
- Outside Air Temperature Sensor Circuit

Diagnostic Fault Information





Circuit/System Description

The HVAC control module monitors the ambient air temperature sensor with a low reference circuit and 5-volt signal circuit. The HVAC control module monitors the voltage drop across the sensor, which is proportional to temperature. When the ambient air temperatures are cold, the resistance of the sensor is high and the voltage signals are high. When the ambient air temperatures are hot, the resistance of the sensors is low and the voltage signals are low.

Conditions for Running the DTC

The ignition is turned ON.

Conditions for Setting the DTC

* The HVAC control module detects the sensor signal circuit is less than -35°C (-39°F).
* The HVAC control module detects the sensor signal circuit is more than 85°C (185°F).

Action Taken When the DTC Sets

The HVAC control module uses a default air temperature value for further automatic control calculations. The default values are not displayed on the scan tool.

Conditions for Clearing the DTC

* The DTC will become history if the HVAC control module no longer detects a failure.
* The history DTC will clear after 100 fault-free ignition cycles.

Reference Information
Schematic Reference

HVAC Schematics (HVAC - Automatic)
Connector End View Reference

Component Connector End Views (Connector Views)
Description and Operation

Automatic HVAC Description and Operation (HVAC - Automatic)
Electrical Information Reference

* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)

Scan Tool Reference

Control Module References (Programming and Relearning)for scan tool information

Circuit/System Verification

Ignition ON, observe the scan tool Outside Air Temp. Sensor Raw parameter. The reading should be between -35°C (-39°F) and 85°C (185°F) and change with ambient air temperature changes.

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the ambient air temp sensor.
2. Ignition OFF, test for less than 10 ohms between the low reference circuit terminal 1 and ground.

If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.

3. Ignition ON, verify the scan tool Outside Air Temp. Sensor Raw parameter is less than -35°C (-39°F).

If greater than the specified range, test the signal circuit terminal 2 for a short to ground. If the circuit tests normal, replace the HVAC control module.

4. Install a 3A fused jumper wire between the signal circuit terminal 2 and the low reference circuit terminal 1. Verify the scan tool Outside Air Temp. Sensor Raw parameter is greater than 85°C (185°F).

If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.

5. If all circuits test normal, test or replace the ambient air temp sensor.

Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.

* Ambient Air Temperature Sensor Replacement (Service and Repair)
* Control Module References (Programming and Relearning)for HVAC control module replacement, setup, and programming