Ambient Air Temperature Malfunction




Ambient Air Temperature Malfunction

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.

Diagnostic Fault Information





Circuit/System Description

The HVAC control module supplies the ambient air temperature sensor with a low reference circuit and signal circuit. The HVAC control module determines the voltage drop across the sensor, which is proportional to temperature. As the air temperature increases, the sensor resistance decreases and the voltage signal decreases. As the air temperature decreases, the sensor resistance increases and the voltage signal increases.

Reference Information
Schematic Reference

HVAC Schematics (Electrical Diagrams)
Connector End View Reference

Component Connector End Views (Connector Views)
Description and Operation

* Air Delivery Description and Operation (Air Delivery Description and Operation)
* Air Temperature Description and Operation (Air Temperature Description and Operation)

Electrical Information Reference

* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)

Scan Tool Reference

Control Module References (Programming and Relearning) for scan tool information

Circuit/System Testing

Important: An instant OAT update must be performed by pressing the A/C and Recirc buttons at the same time after the system has been repaired to convert the A/C permission from out of range to normal.

1. Ignition OFF, disconnect the harness connector at the outside air temperature sensor.
2. Ignition OFF, test for less than 10 ohms of resistance between the low reference circuit terminal B and ground.

If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.

3. Ignition ON, verify the scan tool Ambient Air Temperature sensor parameter is less than -35°F (-37°C).

If greater than the specified range, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module.

4. Install a 3A fused jumper wire between the signal circuit terminal A and the low reference circuit terminal B. Verify the scan tool Ambient Air Temperature sensor parameter is greater than 180°F (82°C).

If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.

5. If all circuits test normal, test or replace the ambient air temperature sensor.

Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.

* Control Module References (Programming and Relearning) for HVAC control module replacement, setup and programming
* Ambient Air Temperature Sensor Replacement (Service and Repair)