Operation CHARM: Car repair manuals for everyone.

P0650




DTC P0650

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview)provides an overview of each diagnostic category.

DTC Descriptor
DTC P0650
- Malfunction Indicator Lamp (MIL) Control Circuit

Diagnostic Fault Information





Circuit/System Description

The malfunction indicator lamp (MIL) is located on the instrument panel cluster (IPC).

The MIL informs the driver that an emission system fault has occurred and that the engine control system requires service. The control module monitors the MIL control circuit for conditions that are incorrect for the commanded states of the MIL.

Conditions for Running the DTC

* The ignition is in the Run or Crank position.
* The ignition voltage is between 9-18 volts.
* DTC P0650 runs continuously when the ignition is ON.

Conditions for Setting the DTC

The control module detects that the commanded state of the MIL driver and the actual state of the control circuit do not match for more than 5 seconds.

Action Taken When the DTC Sets

DTC P0650 is a Type B DTC.

Conditions for Clearing the MIL/DTC

DTC P0650 is a Type B DTC.

Reference Information
Schematic Reference

* Instrument Cluster Schematics (Instrument Cluster Schematics)
* Engine Controls Schematics (Electrical Diagrams)

Connector End View Reference

Component Connector End Views (Connector Views)
Electrical Information Reference

* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions (Diagnostic Trouble Code Descriptions)
Scan Tool Reference

Control Module References (Programming and Relearning)for scan tool information

Circuit/System Verification

Ignition ON, the MIL should turn ON and OFF when commanded with a scan tool.

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the IPC.
2. Ignition ON, verify that a test lamp illuminates between the ignition circuit and ground.

If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, replace the IPC.

3. Connect a test lamp between the control circuit and the ignition circuit.
4. Command the MIL ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.

If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM.
If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.

5. If all circuits test normal, replace the IPC.

Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.

* Instrument Cluster Replacement (Service and Repair)
* Control Module References (Programming and Relearning)for ECM replacement, setup, and programming