Operation CHARM: Car repair manuals for everyone.

Turn Signal Lamps and/or Indicators Malfunction




Turn Signal Lamps and/or Indicators Malfunction

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Diagnostic System Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Strategy Based Diagnosis) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Diagnostic Procedure Instructions) provides an overview of each diagnostic category.

Diagnostic Fault Information





Circuit/System Description

Ground is applied at all times to the turn signal/multifunction switch. The turn signal lamps may only be activated with the ignition switch in the ON or START position. When the turn signal/multifunction switch is placed in either the TURN RIGHT or TURN LEFT position, ground is applied to the body control module (BCM) through either the right turn or left turn signal switch signal circuit. The BCM then applies a pulsating voltage to the front and rear turn signal lamps through there respective voltage supply circuits.

Reference Information
Schematic Reference

Exterior Lights Schematics (Exterior Lights Schematics)
Connector End View Reference

Component Connector End Views (Connector End Views By Name)
Description and Operation

Exterior Lighting Systems Description and Operation (Exterior Lighting Systems)
Electrical Information Reference

* Circuit Testing (Circuit Testing)
* Connector Repairs (Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (Wiring Repairs)

Scan Tool Reference

Control Module References (Programming and Relearning) for scan tool information

Circuit/System Verification

1. Ignition ON, observe the scan tool Right Turn Signal Switch and Left Turn Signal Switch parameters while cycling the turn signal switch between the right and left positions. The readings should change between Active and Inactive.

If the parameters do not change between the selected states, refer to Turn Signal Switch Malfunction.

2. Ignition ON, observe the right and left turn signal lamps while cycling the turn signal switch between the right and left positions. Verify the turn signal lamps turn ON and OFF.

If the turn signal lamps do not cycle between the selected states, refer to Turn Signal Lamps Malfunction.

3. Command the Display Test ON and OFF with a scan tool. The left and right turn signal indicators should turn ON and OFF when changing between the commanded states.

If the left and right turn signal indicators illuminate during the test, replace the BCM.
If the left and right turn signal indicators do not illuminate during the test or remain illuminated at all times, replace the instrument cluster.

Circuit/System Testing

Turn Signal Switch Malfunction
1. Ignition OFF, disconnect the X4 harness connector at the turn signal/multifunction switch.
2. Ignition OFF, verify that a test lamp illuminates between B+ and the ground circuit terminal G.

If the test lamp does not illuminate, test the ground circuit for an open/high resistance.

3. Ignition ON, verify the scan tool Left Turn Signal Switch parameter is Inactive.

If not the specified value, test the signal circuit terminal F for a short to ground. If the circuit tests normal, replace the BCM.

4. Verify the scan tool Right Turn Signal Switch parameter is Inactive.

If not the specified value, test the signal circuit terminal H for a short to ground. If the circuit tests normal, replace the BCM.

5. Install a 3 A fused jumper wire between the signal circuit terminal F and ground. Verify the scan tool Left Turn Signal Switch parameter is Active.

If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.

6. Install a 3 A fused jumper wire between the signal circuit terminal H and ground. Verify the scan tool Right Turn Signal Switch parameter is Active.

If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.

7. If all circuits test normal, test or replace the turn signal/multifunction switch.

Turn Signal Lamps Malfunction
1. Ignition OFF, disconnect the harness connector at the appropriate turn signal lamp.
2. Ignition OFF, exterior lamps OFF, test for less than 5 ohm between the ground circuit terminal listed below and ground.

* Turn Signal Lamp Front - Terminal GRD
* Park/Turn Signal Lamp - Terminal G
* Turn Signal Lamp Rear - Terminal 1
* Tail/Stop and Turn Signal Lamp - Terminal 1

If greater than the specified range, test the ground circuit for an open/high resistance.

3. Connect a test lamp between the control circuit terminal listed below and the ground circuit terminal.

* Turn Signal Lamp Front - Terminal MAJOR
* Park/Turn Signal Lamp - Terminal A
* Turn Signal Lamp Rear - Terminal 3
* Tail/Stop and Turn Signal Lamp - Terminal 3

4. Command the appropriate Turn Signal Lamp ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.

If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.

5. If all circuits test normal, replace the turn signal lamp.

Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.

* Outside Rearview Mirror Turn Signal Lamp Replacement (T90 Europe Japan) (Service and Repair)
* Tail Lamp Replacement (Service and Repair)
* Tail Lamp Bulb Replacement (Service and Repair)
* Turn Signal Multifunction Switch Replacement (Service and Repair)
* Control Module References (Programming and Relearning) for BCM or IPC replacement, setup, and programming