Operation CHARM: Car repair manuals for everyone.

P0621




DTC P0621

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Diagnostic System Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Strategy Based Diagnosis) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Diagnostic Procedure Instructions)provides an overview of each diagnostic category.

DTC Descriptor
DTC P0621
- Generator L-Terminal Circuit

Diagnostic Fault Information





Circuit/System Description

The engine control module (ECM) uses the generator turn ON control circuit to control the load of the generator on the engine. A high side driver in the ECM applies a voltage to the voltage regulator. This signals the voltage regulator to turn the field circuit ON and OFF. The ECM monitors the state of the generator turn ON control circuit. The ECM should detect low voltage on generator turn on control circuit when the ignition is ON and the engine is OFF, or when the charging system malfunctions. With the engine running, the ECM should detect high voltage on the generator turn ON control circuit. The ECM performs the ignition ON and RUN tests to determine the status of the generator turn ON control circuit.

Conditions for Running the DTC

* No generator, crankshaft position (CKP) sensors, or camshaft position (CMP) sensor DTCs are set.
* The ignition ON, engine OFF for the ignition on test.
* The engine running for the run test.

Conditions for Setting the DTC

* During the ignition ON test, the ECM detects high voltage on the generator turn ON control circuit for 5 seconds.
* During the RUN test, the ECM detects low voltage on the generator turn ON control circuit for 15 seconds.

Action Taken When the DTC Sets

* The instrument panel cluster (IPC) illuminates the charge indicator.
* The driver information center (DIC) displays the SERVICE BATTERY CHARGING SYSTEM warning message.

Conditions for Clearing the DTC

DTC P0621 is a C type DTC.

Reference Information
Schematic Reference

Starting and Charging Schematics (Electrical Diagrams)
Connector End View Reference

Component Connector End Views (Connector End Views By Name)
Description and Operation

Charging System Description and Operation (Description and Operation)
Electrical Information Reference

* Circuit Testing (Circuit Testing)
* Connector Repairs (Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (Wiring Repairs)

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions (Powertrain Diagnostic Trouble Code (DTC) Type Definitions)
Scan Tool Reference

Control Module References (Programming and Relearning)for scan tool information

Circuit/System Testing

1. Verify that a test lamp illuminates between the generator B+ terminal A X2 and ground.

If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.

2. Ignition OFF, disconnect the X1 harness connector at the generator.
3. Ignition ON, test for 4.5-5.5 V between the control circuit terminals 1 X1 and ground.

If greater than the specified range, test the control circuit for a short to voltage. If the circuit tests normal, replace the ECM.
If less than the specified range, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal replace the ECM.

4. If the circuits test normal, replace the generator.

Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.

* Generator Replacement (LGD/LZE) (Service and Repair)
* Control Module References (Programming and Relearning)for ECM replacement, programming and setup