B0193




DTC B0193

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.

* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC B0193 01
- Front Blower Motor Speed Circuit Short to Battery

DTC B0193 06
- Front Blower Motor Speed Circuit Low Voltage/Open

Diagnostic Fault Information






Circuit/System Description

The blower motor control module is an interface between the HVAC control module and the blower motor. The blower motor speed control from the HVAC control module, battery positive and ground circuits enable the blower motor control module to operate. The HVAC control module provides a pulse width modulation (PWM) signal to the blower motor control module in order to command the blower motor speed. The blower motor control module transfers the PWM signal into a corresponding blower motor voltage. The voltage resides between 2-13 V and changes linear to the height of the PWM signal.

Conditions for Running the DTC

* Ignition ON.

* The HVAC control module is ON.

Conditions for Setting the DTC

B0193 01

The voltage at the HVAC control module output to the blower motor control module is always high.

B0193 06

The voltage at the HVAC control module output to the blower motor control module is always low or floating.

Action Taken When the DTC Sets

The blower motor is inoperative.

Conditions for Clearing the DTC

The condition for setting the DTC is no longer present.

Diagnostic Aids

Prior to motor replacement connect a direct independent B+ and ground to verify operation.

Inspect the motor shaft for rust or other foreign material which may prohibit proper motor operation.

If the motor operates properly please reinstall it, check for PIs or TSBs, and refer to Testing for Intermittent Conditions and Poor Connections in the Electrical Information Reference section of this document.

Reference Information

Schematic Reference

HVAC Schematics Electrical Diagrams

Connector End View Reference

Component Connector End Views Fuel Pump and Level Sensor Assembly - Primary

Description and Operation

Manual HVAC Description and Operation HVAC - Manual

Electrical Information Reference

* Circuit Testing Circuit Testing

* Connector Repairs Connector Repairs

* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections

* Wiring Repairs Wiring Repairs

Scan Tool Reference

Control Module References Control Module References for scan tool information

Circuit/System Testing

1. Ignition OFF, disconnect the X1 harness connector at the K8 blower motor control module. It may take up to 2 minutes for all vehicle systems to power down.

2. Test for less than 10 ohms between the ground circuit terminal 5 and ground.

If 10 ohms or greater

1. Ignition OFF.

2. Test for less than 2 ohms in the ground circuit end to end.

If 2 ohms or greater, repair the open/high resistance in the circuit.

If less than 2 ohms, repair the open/high resistance in the ground connection.

If less than 10 ohms

3. Ignition ON, verify a test lamp illuminates between B+ circuit terminal 6 and ground.

If the test lamp does not illuminate and the circuit fuse is good

1. Ignition OFF.

2. Test for less than 2 ohms in the B+ circuit end to end.

If 2 ohms or greater, repair the open/high resistance in the circuit.

If less than 2 ohms, verify the fuse is not open and there is voltage at the fuse.

If the test lamp does not illuminate and the circuit fuse is open

1. Ignition OFF.

2. Test for infinite resistance between the B+ circuit terminal 6 and ground.

If less than infinite resistance, repair the short to ground on the circuit.

If infinite resistance, replace the K8 blower motor control module.

If the test lamp illuminates

4. Connect a DMM between the control circuit X1 terminal 3 and the B+ circuit terminal 6.

5. Verify the proper voltages when changing the blower speed positions.

* OFF 13.0 V-11.0 V

* HI 3.0 V-1.0 V

If not within the specified range

1. Ignition OFF, disconnect the harness connector at the K33 HVAC control module.

2. Test for less than 1 V between the control circuit terminal 3 and ground.

If 1 V or greater, repair the short to voltage on the circuit.

If less than 1 V

3. Test for infinite resistance between the control circuit and ground.

If less than infinite resistance, repair the short to ground on the circuit.

If infinite resistance, replace the K33 HVAC control module.

If within the specified range

6. Connect the X1 harness connector at the K8 blower motor control module. Disconnect the X2 harness connector at the K8 blower motor control module.

7. Connect a DMM between the control circuit terminal 2 on the K8 blower motor control module and B+.

8. Verify the proper voltages when changing the blower speed positions.

* OFF 0 V-3.0 V

* HI 10.0 V-13.0 V

If not within the specified range
Replace the K8 blower motor control module.

If within the specified range

9. Verify a test lamp illuminates between B+ circuit terminal 1 and ground.

If the test lamp does not illuminate
Replace the K8 blower motor control module.

If the test lamp illuminates

10. Replace the M8 blower motor.

Repair Instructions

Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.

* HVAC Component Replacement Reference Removal and Replacement

* Control Module References Control Module References for HVAC control module replacement, setup, and programming