Operation CHARM: Car repair manuals for everyone.

B2545




DTC B2545

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.

* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC B2545 01

-
Backup Lamps Circuit Short to Battery

DTC B2545 02

-
Backup Lamps Circuit Short to Ground

DTC B2545 04

-
Backup Lamps Circuit Open

Diagnostic Fault Information






Circuit/System Description

When the transmission is placed in the REVERSE position with the engine running, the transmission control module (TCM) sends a serial data message to the body control module (BCM). The message indicates that the gear selector is in the REVERSE position. The BCM applies ground to the backup lamp relay control circuit energizing the backup lamp relay coil. With the relay coil energized, the switch contacts close allowing battery voltage to flow from the backup lamps fuse to the left and right backup lamps. Once the driver moves the gear selector out of the REVERSE position, a message is sent by the TCM via serial data requesting the BCM to remove ground from the backup lamp relay control circuit.

Conditions for Running the DTC

Battery voltage must be between 9-16 V.

Conditions for Setting the DTC

B2545 01

The DTC will set when the BCM detects a short to voltage in the backup lamp relay control circuit.

B2545 06

The DTC will set when the BCM detects a short to ground or an open in the backup lamp relay control circuit.

Action Taken When the DTC Sets

* When DTC B2545 01 is present, the backup lamps will not operate.

* When DTC B2545 06 is present, the backup lamps will be ON at all times or will not operate.

Conditions for Clearing the DTC

* The condition responsible for setting the DTC no longer exists.

* A history DTC will clear once 100 consecutive malfunction free ignition cycles have occurred.

Reference Information

Schematic Reference

Exterior Lights Schematics Exterior Lights Schematics

Connector End View Reference

Component Connector End Views Sunshade - Left (DH6)

Description and Operation

Exterior Lighting Systems Description and Operation Exterior Lighting Systems

Electrical Information Reference

* Circuit Testing Circuit Testing

* Connector Repairs Connector Repairs

* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections

* Wiring Repairs Wiring Repairs

Scan Tool Reference

Control Module References Control Module References for scan tool information

Circuit/System Testing

1. Ignition OFF, disconnect the KR40 Backup Lamp Relay.

2. Verify that a test lamp illuminates between the B+ circuit terminal 30 and ground.

If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 87 for a short to ground. If the circuit tests normal, test or replace the KR40 Backup Lamp Relay.

3. Verify that a test lamp illuminates between the B+ circuit terminal 85 and ground.

If the test lamp does not illuminate, test the B+ circuit for an open/high resistance.

4. Connect a test lamp between the B+ circuit terminal 85 and the control circuit terminal 86.

5. Command the Backup Lamps ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.

If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the K9 Body Control Module.

If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K9 Body Control Module.

6. If all circuits test normal, test or replace the KR40 Backup Lamp Relay.

Repair Instructions

Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.

* Relay Replacement (Within an Electrical Center) Relay Replacement (Within an Electrical Center)Relay Replacement (Attached to Wire Harness) Relay Replacement (Attached to Wire Harness)

* Control Module References Control Module References for BCM replacement, programming and setup