Air Delivery Improper
Air Delivery Improper
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.
Diagnostic Fault Information
Circuit/System Description
With the defrost switch, air to foot well switch, air to windscreen switch and the air to head area switch at the HVAC controls, the wished air distribution flap position can be put in. The selected value is sent to the HVAC control module via LIN-Bus. The HVAC control module supplies a 12 V reference voltage to the stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motor puts the air distribution flap into the selected position.
Diagnostic Aids
Check the following mechanical fault sources:
* Air distribution box
* Air distribution hoses/air distributing ducts
Reference Information
Schematic Reference
HVAC Schematics HVAC - Automatic
Connector End View Reference
Component Connector End Views Sunshade - Left (DH6)
Description and Operation
Automatic HVAC Description and Operation HVAC - Automatic
Electrical Information Reference
* Circuit Testing Circuit Testing
* Connector Repairs Connector Repairs
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections
* Wiring Repairs Wiring Repairs
Scan Tool Reference
Control Module References Control Module References for scan tool information
Circuit/System Testing
1. Ignition ON, press and release the switch for air distribution to head. Verify the scan tool Front Defrost Switch parameter changes between Active and Inactive.
• If the parameter does not change
Replace the A26 HVAC Controls.
• If the parameter changes
2. Press and release the switch for air distribution to face. Verify the scan tool Instrument Panel Vents switch parameter changes between Active and Inactive.
• If the parameter does not change
Replace the A26 HVAC Controls.
• If the parameter changes
3. Press and release the switch for air distribution to floor. Verify the scan tool Floor Mode Switch parameter changes between Active and Inactive.
• If the parameter does not change
Replace the A26 HVAC Controls.
• If the parameter changes
4. Press and release the defrost switch. Verify the scan tool Enhanced Defrost Switch parameter changes between Active and Inactive.
• If the parameter does not change
Replace the A26 HVAC Controls.
• If the parameter changes
5. Replace the M37 Mode Door Actuator and verify the M37 Mode Door Actuator can be put into all positions.
• If the M37 Mode Door Actuator cannot be put into all positions
Replace the K33 HVAC Control Module.
• If the M37 Mode Door Actuator can be put into all positions
6. All OK.
Repair Instructions
Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.
* Mode Control Cam Actuator Replacement Mode Control Cam Actuator Replacement
* Heater and Air Conditioning Control Replacement Heater and Air Conditioning Control Replacement
* Control Module References Control Module References for HVAC control module replacement, programming and setup